Removal Procedure
Caution: Do not allow smoking or the use of open flames in the area where work on the
fuel or EVAP system is taking place. Anytime work is being done on the
fuel system, disconnect the negative battery cable, except for those tests where battery
voltage is required.
- Turn ignition OFF.
- Disconnect both purge link quick connects from the evaporative emission
(EVAP) purge solenoid.
- Disconnect the EVAP purge solenoid harness connector.
- Slide the EVAP purge solenoid from the retaining bracket.
Installation Procedure
- Slide
the EVAP purge solenoid into the retaining bracket.
- Connect the purge line quick connects to the EVAP purge solenoid. Push
in the connector until a slick is heard, then pull back to confirm positive engagement.
- Connect the EVAP purge solenoid harness connector.