Removal Procedure
- Disconnect the evaporative emission (EVAP) canister purge valve harness connector (1).
- Disconnect the vacuum pipe (2) from the EVAP canister purge valve.
- Disconnect the purge pipe (3) from the EVAP canister purge valve.
- Remove the EVAP canister purge valve and bracket.
- Remove the EVAP canister purge valve from the purge bracket.
- Inspect for carbon release in the EVAP canister purge valve ports. Refer to
Evaporative Emission System Cleaning
.
Installation Procedure
- Install the EVAP canister purge valve on to the purge bracket.
Notice: Refer to Fastener Notice in the Preface section.
- Install the EVAP canister purge valve and bracket.
Tighten
Tighten the purge bracket nut to 8 N·m (71 lb in).
- Connect the purge pipe (2) to the EVAP canister purge valve.
- Connect the vacuum pipe (3) to the EVAP canister purge valve.
- Connect the EVAP canister purge valve harness connector (1).