Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C Performance Table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 151-241 kPa (22-35 psi) | 861-1136 kPa (125-165 psi) | 9°C (48°F) |
19-24°C (66-75°F) | Less than 40% | 151-261 kPa (22-38 psi) | 999-1309 kPa (145-190 psi) | 10°C (50°F) |
Greater than 40% | 165-296 kPa (24-43 psi) | 1026-1350 kPa (149-196 psi) | 13°C (55°F) | |
25-29°C (76-85°F) | Less than 35% | 199-296 kPa (29-43 psi) | 1198-1467 kPa (174-213 psi) | 13°C (55°F) |
35-50% | 213-310 kPa (31-45 psi) | 1219-1488 kPa (177-216 psi) | 14°C (57°F) | |
Greater than 50% | 227-330 kPa (33-48 psi) | 1240-1529 kPa (180-222 psi) | 17°C (61°F) | |
30-35°C (86-95°F) | Less than 30% | 241-351 kPa (35-51 psi) | 1357-1660 kPa (197-241 psi) | 18°C (63°F) |
30-50% | 254-358 kPa (37-52 psi) | 1378-1701 kPa (200-247 psi) | 18°C (64°F) | |
Greater than 50% | 268-378 kPa (39-55 psi) | 1412-1750 kPa (205-254 psi) | 20°C (68°F) | |
36-41°C (96-105°F) | Less than 20% | 296-399 kPa (43-58 psi) | 1543-1832 kPa (224-266 psi) | 22°C (70°F) |
20-40% | 303-406 kPa (44-59 psi) | 1557-1880 kPa (226-273 psi) | 23°C (72°F) | |
Greater than 40% | 316-413 kPa (46-60 psi) | 1598-1922 kPa (232-279 psi) | 23°C (73°F) | |
42-46°C (106-115°F) | Less than 20% | 351-447 kPa (51-65 psi) | 1729-1998 kPa (251-290 psi) | 24°C (75°F) |
Greater than 20% | 358-447 kPa (52-65 psi) | 1750-2053 kPa (254-298 psi) | 25°C (77°F) | |
47-49°C (116-120°F) | Below 30% | 406-496 kPa (59-72 psi) | 1922-2259 kPa (279-328 psi) | 28°C (82°F) |
Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C Performance Table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 151-213 kPa (22-31 psi) | 1260-1440 kPa (183-209 psi) | 9°C (48°F) |
19-24°C (66-75°F) | Less than 40% | 158-248 kPa (23-36 psi) | 1419-1577 kPa (206-229 psi) | 12°C (52°F) |
Greater than 40% | 172-261 kPa (25-38 psi) | 1460-1564 kPa (212-227 psi) | 13°C (54°F) | |
25-29°C (76-85°F) | Less than 35% | 192-275 kPa (28-40 psi) | 1557-1805 kPa (226-262 psi) | 13°C (54°F) |
35-50% | 206-282 kPa (30-41 psi) | 1505-1798 kPa (219-261 psi) | 13°C (54°F) | |
Greater than 50% | 213-296 kPa (31-43 psi) | 1467-1791 kPa (213-260 psi) | 14°C (57°F) | |
30-35°C (86-95°F) | Less than 30% | 220-303 kPa (32-44 psi) | 1598-1901 kPa (232-276 psi) | 15°C (59°F) |
30-50% | 234-316 kPa (34-46 psi) | 1329-1632 kPa (193-237 psi) | 17°C (61°F) | |
Greater than 50% | 241-337 kPa (35-49 psi) | 1350-1550 kPa (196-225 psi) | 18°C (64°F) | |
36-41°C (96-105°F) | Less than 20% | 254-330 kPa (37-48 psi) | 1543-1756 kPa (224-255 psi) | 18°C (64°F) |
20-40% | 261-344 kPa (38-50 psi) | 1543-1701 kPa (224-247 psi) | 18°C (64°F) | |
Greater than 40% | 268-358 kPa (39-52 psi) | 1577-1646 kPa (229-239 psi) | 19°C (66°F) | |
42-46°C (106-115°F) | Less than 20% | 282-358 kPa (41-52 psi) | 1708-1798 kPa (248-261 psi) | 19°C (66°F) |
Greater than 20% | 268-378 kPa (39-55 psi) | 1619-1743 kPa (235-253 psi) | 20°C (68°F) | |
47-49°C (116-120°F) | Below 30% | 316-399 kPa (46-58 psi) | 1722-1942 kPa (250-282 psi) | 22°C (70°F) |
Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C Performance Table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C Performance Table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 151-206 kPa (22-30 psi) | 1109-1329 kPa (161-193 psi) | 8°C (46°F) |
19-24°C (66-75°F) | Less than 40% | 151-227 kPa (22-33 psi) | 1205-1481 kPa (175-215 psi) | 9°C (48°F) |
Greater than 40% | 151-254 kPa (22-37 psi) | 1288-1495 kPa (187-217 psi) | 12°C (52°F) | |
25-29°C (76-85°F) | Less than 35% | 172-261 kPa (25-38 psi) | 1433-1688 kPa (208-245 psi) | 12°C (52°F) |
35-50% | 186-268 kPa (27-39 psi) | 1398-1722 kPa (203-250 psi) | 13°C (54°F) | |
Greater than 50% | 192-296 kPa (28-43 psi) | 1378-1722 kPa (200-250 psi) | 14°C (57°F) | |
30-35°C (86-95°F) | Less than 30% | 206-296 kPa (30-43 psi) | 1522-1929 kPa (221-280 psi) | 14°C (57°F) |
30-50% | 213-310 kPa (31-45 psi) | 1343-1646 kPa (195-239 psi) | 15°C (59°F) | |
Greater than 50% | 234-337 kPa (34-49 psi) | 1357-1591 kPa (197-231 psi) | 18°C (63°F) | |
36-41°C (96-105°F) | Less than 20% | 241-330 kPa (35-48 psi) | 1584-1818 kPa (230-264 psi) | 17°C (61°F) |
20-40% | 248-344 kPa (36-50 psi) | 1577-1777 kPa (229-258 psi) | 18°C (64°F) | |
Greater than 40% | 261-365 kPa (38-53 psi) | 1591-1729 kPa (231-251 psi) | 19°C (66°F) | |
42-46°C (106-115°F) | Less than 20% | 282-365 kPa (41-53 psi) | 1729-1922 kPa (251-279 psi) | 19°C (66°F) |
Greater than 20% | 289-378 kPa (42-55 psi) | 1743-1860 kPa (253-270 psi) | 20°C (68°F) | |
47-49°C (116-120°F) | Below 30% | 323-406 kPa (47-59 psi) | 1839-2073 kPa (267-301 psi) | 23°C (72°F) |