• | J 44017 Shaft Remover |
• | SA9133T Slide Hammer |
Important:
• Remove the retainer ring from the stub shaft for tool installation. Discard the used retainer ring. • Use the proper container for fluid loss when the stub shaft is removed. Plug power take-off unit (PTU) to minimize fluid loss.
Important: Index mark the propshaft to PTU for re-installation.
Important: Lubricate the seal with transmission fluid prior to PTU installation.
Notice: Refer to Fastener Notice in the Preface section.
Tighten
Tighten the bolts to 60 N·m (44 lb ft).
Tighten
Tighten the bolts to 60 N·m (44 lb ft).
Important: Use the index mark for reassembly.
Important: Apply Permatex Threadlocker®-Blue to bolt threads.
Tighten
Tighten the bolts to 25 N·m (19 lb ft).
Tighten
Tighten the bolts to 25 N·m (19 lb ft).
Important: Use sealant GM P/N 12345493 or equivalent on fill plug.
Specification
Add 500 ml (17 oz) PTU fluid.
Tighten
Tighten the fill plug to 15 N·m (11 lb ft).