Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Floor Flood Lamp Switch Voltage Supply Circuit | 2 | 2 | -- | -- |
Floor Flood Lamp Voltage Supply Circuit | 1, 2 | 1, 2 | 1, 3 | -- |
Floor Flood Lamp Ground Circuit | -- | 2 | 2 | -- |
1. Only One Color Inoperative 2. Floor Flood Lamps Inoperative 3. Floor Flood Lamps Always ON |
The floor flood lamps switch is supplied voltage only when the ignition is in the RUN position. When the ignition heated is placed in the RUN position, the floor flood lamps are supplied 12 volts from the seat fuse. The floor flood lamp switch has three settings OFF, Amber, and Blue. When the floor flood lamp switch is placed in the Amber or Blue setting voltage is supplied to the proper lighting circuit to illuminate the appropriate color. There are four Light Emitting Diodes (LED) per front seat (two for the BLUE and two for the AMBER). One set of lights are facing forward and is mounted on the inside or the outer seat track. The other set of LEDs are mounted in the rear of the front seat cushion.
If one color illuminates and the other does not illuminates test the proper supply circuit for a shout to ground or an open/high resistance. If one lamp illuminates one color and the other does not illuminate inspect the wiring for an open in the floor flood lamp circuits. If no problem is found replace the floor flood lamps assembly.
Lighting Systems Connector End Views
Ignition ON, observe the lights under the passenger and drivers seats while placing the appropriate front seat flood lams switch in either the BLUE or AMBER setting. Both of the lights under the seat should illuminate in the proper color when commanded.
⇒ | If the test lamp does not illuminate, test the failed circuit for a short to ground or an open/high resistance. |
⇒ | If greater than 1.0 ohm, test the ground circuit for an open/high resistance. |
⇒ | If B+ is not present on one or both circuits, test the signal circuit for an open/high resistance. If the circuit tests normal, test or replace the floor flood lamp switch. |
⇒ | If the back lighting does not illuminate, replace the floor flood switch. |
⇒ | If the seat lighting switches do not illuminate replace the floor flood lamps switch. |
⇒ | If one or both lights do not illuminate the proper color, replace the floor flood lamps assemble. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.