• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of the diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Relay Switch B+ Circuit | 2 | 2 | -- | -- |
Relay Coil B+ Circuit | 2 | 2 | -- | -- |
HVAC B+ Circuit | 2 | 2 | -- | -- |
Rear Defogger Relay Control | B0285 | B0286 | B0286 | -- |
Relay Controlled Output Circuit | 2 | 2 | 3 | -- |
Rear Defogger Switch Signal | 2 | 2 | 2 | -- |
Defog Switch Ground | -- | 1,2 | 1,2 | -- |
Rear Window Defogger Grid Ground | -- | 2 | 2 | -- |
1. HVAC Defogger Indicator Inoperative 2. Rear Defogger Inoperative 3. Rear Defogger Always ON |
Battery positive voltage is supplied through the REAR DEFOG fuse in the underhood fuse block to the REAR DEFOG relay switched input. Ground for the coil of the REAR DEFOG relay is provided by the body control module (BCM). Battery voltage is supplied from the IGNITION 30A MaxiFuse to the supply voltage on the rear defog relay coil side. When you depress the rear defogger switch, the rear defogger switch pulls the signal circuit low as an input to the BCM. The BCM interprets this as a request for the rear defogger system. The BCM enables the rear defogger system by supplying ground to the REAR DEFOG relay coil. The relay coil ground is also spliced off to the ground circuit of the rear defogger indicator. The REAR DEFOG relay is energized and the rear defogger indicator is illuminated. With the relay energized, battery positive voltage is allowed from the relay switched input through the switch contacts and out the relay switched output to the rear defogger grid. Ground for the rear defogger grid is provided by G401. When you start the engine and press the rear defogger switch for the first time, the defogger cycle lasts for 15 minutes. Further operation results in 7.5 minute defogger cycles. The defogger cycle resets to 15 minutes when you cycle the ignition to the OFF position and then to the ON position.
Window Systems Connector End Views
Power Windows Description and Operation
⇒ | If the reading does not change between the commanded states, refer to Rear Defogger Switch Malfunction. |
⇒ | If the rear window defogger does not turn ON and OFF when changing between the commanded states, refer to Rear Defogger Malfunction. |
⇒ | If the Defogger indicator does not illuminate, replace the HVAC control module. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If not the specified value, test the signal circuit terminal 1 for a short to ground. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp illuminates, test the relay controlled output circuit for a short to voltage. |
⇒ | If the test lamp does not illuminate, test the relay coil B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the B+ circuit fuse is open, test or replace the relay REAR DEFOG relay. |
⇒ | If the test lamp does not illuminate, test the relay switch B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal and the REAR DEFOG fuse is open, test the relay controlled output circuit for a short to ground. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the rear window defogger grid does not activate, test the relay controlled output circuit for an open/high resistance. If the circuit tests normal, test or replace the rear window defogger grid. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the relay coil control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp remains bright at the middle of the grid line, test for an open between the test point and the ground side of the grid. |
⇒ | If the test lamp remains off at the middle of the grid line, test for an open between the test point and the voltage supply side of the grid. |
⇒ | If the resistance is not within the specified range, replace the relay. |
• | 30 and 86 |
• | 30 and 87 |
• | 30 and 85 |
• | 85 and 87 |
⇒ | If not the specified value, replace the relay. |
⇒ | If greater than the specified range, replace the relay. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for HVAC control module replacement, setup, and programming |