GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC P1A9E: Starter/Generator Inverter Phase U Overtemperature

DTC P1AA2: Starter/Generator Inverter Phase V Overtemperature

Circuit/System Description

The power inverter module (PIM) temperature 1/2 sensor is used for overheat protection. The thermistor is located on the control board, near the phase U/V power MOSFET. The SGCM monitors the inverter temperature sensor for the following:

    • To detect if the inverter phase U/V temperature sensor is shorted low.
    • To detect if the inverter phase U/V temperature sensor is shorted high.

If one of the above conditions is detected, the MGU will set the appropriate DTC.

Conditions for Running the DTC

P1A9E, P1AA2

The engine is running.

Conditions for Setting the DTC

P1A9E, P1AA2

Temperature is greater than 175°C (347°F) for 20 ms.

Action Taken When the DTC Sets

P1A9E, P1AA2

Stop PWM (MGU shutdown)

Conditions for Clearing the DTC

P1A9E, P1AA2

Temperature is less than 150°C (302°F) for 2.5 seconds.

Diagnostic Aids

PP1A9E, P1AA2

Possible cooling system failure due to the following:

    • Restricted radiator air flow
    • Restricted engine coolant flow
    • Faulty thermostat
    • Faulty engine water pump
    • Inoperative SGCM water pump

Reference Information

Schematic Reference

Hybrid Controls Schematics

Connector End View Reference

Hybrid Controls Connector End Views

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Scan Tool Data List

Circuit/System Testing

Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.

  1. Inspect the 3 phase cable connections at the SGCM. Refer to Generator Control Module Replacement .
  2. Verify that the 3 phase cables are torqued to within specifications. Refer to Fastener Tightening Specifications .
  3. If the 3 phase cables are within specifications, replace the SGCM.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

Control Module References for SGCM replacement, setup, and programming