Important: This test is for reference only. A grid line fault requires rear window replacement. Refer to Liftgate Window Replacement .
Important: The test lamp brilliance will decrease proportionately to the increased resistance in the grid line as the probe is moved from the battery positive bus wire to the ground bus wire. The test lamp brilliance may vary from one window to another.
• | If the test lamp shows full brilliance at both ends of the grid lines, inspect for an open or poor connection in the ground circuit of the rear window defogger grid. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs. |
• | If the test lamp goes out, test the grid line in at least 2 places to eliminate the possibility of bridging the open in the grid line. |