Removal Procedure
- Remove the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement .
- Disconnect the electrical connector from the panel actuator.
- Remove the panel actuator screws from the HVAC module.
- Remove the panel actuator from the HVAC module.
Installation Procedure
- Align the panel actuator with the door shaft and rotate
into position.
Notice: Refer to Fastener Notice in the Preface section.
- Install the panel actuator screws to the HVAC module.
Tighten
Tighten the screws to 1 N·m (9 lb in).
- Connect the electrical connector to the panel actuator.
Important: Any time a mode actuator or the HVAC control
module is replaced, the HVAC control module must be calibrated to ensure proper air
distribution.
- Calibrate the mode actuators by simultaneously pushing the A/C and RECIRC buttons
on the HVAC control module 3 times each, within 2 seconds of initial
push.
4.1. | The A/C and RECIRC button LED's will flash while this calibration is taking
place. |
4.2. | The calibration will take anywhere between 10 to 30 seconds depending
on battery voltage. |
4.3. | The LEDs will quit flashing when the calibration is complete. |
- Cycle the ignition and verify proper operation.
- Install the instrument panel compartment. Refer to
Instrument Panel Compartment Replacement
.