Cooling System Draining and Filling Static Fill

Draining Procedure

    Caution: In order to avoid personal injury, do not remove the cap or open the cooling system drains from a hot system. Allow the system to cool first.


    Object Number: 1922919  Size: SH

    Important: A 7.6 liter (8 qt) coolant container will be needed.

  1. Place the coolant container under the radiator drain cock located at the bottom of the right radiator end tank.
  2. Open the drain cock and drain the coolant. A small amount of coolant will drain from the system.

  3. Object Number: 1922923  Size: SH
  4. Remove the surge tank cap from the surge tank and the coolant will drain from the system.

  5. Object Number: 964352  Size: SH
  6. For LE5 and LAT vehicles, if the engine block needs to be drained, a drain bolt is located near the bottom of the water pump assembly.
  7. Inspect the coolant.
  8. Follow the appropriate procedure based on the condition of the coolant.
  9. • Normal in appearance--follow the filling procedure.
    • Discolored--follow the flush procedure. Refer to Coolant System Flushing .

Filling Procedure

    Notice: All entrapped air must be purged from the powertrain cooling system before the final coolant level can be determined. Proper coolant level is critical to avoid engine damage.

    Important: The vehicle must be level when filling the cooling system.

  1. Slowly add a mixture of 50/50 DEX-COOL antifreeze and clean water to the coolant surge tank. Fill the cooling system as indicated below:
  2. • For LE5/LAT vehicles when the engine block is not drained, add 3.5 liters (3.7 qts)
    • For LE5/LAT vehicles when the engine block is drained, add 6 liters (6.3 qts)
    • For LZ4/LY7 vehicles, add 5 liters (5.3 qts)
  3. Start the engine and check for leaks.
  4. Run the engine and cycle the vehicle from idle to 3,000 RPM in 30 second intervals until the engine cooling fan comes ON, the engine cooling fan turns ON at approximately 102°C (216°F). Repeat this process twice before the engine is turned OFF.
  5. Return the engine to idle, and idle for 30 seconds, then turn the engine OFF.
  6. Allow the vehicle to cool, before adding additional coolant.
  7. Important: The level in the surge tank will return into the cold fill range once the vehicle cools.

  8. Add additional coolant to the surge tank until the level is approximately 13 mm (0.5 in) above the surge tank seam.
  9. Install the coolant surge tank cap.

Cooling System Draining and Filling GE 47716 Fill

Tools Required

    • J 26568 Coolant and Battery Fluid Tester
    • GE-47716 Vac N Fill Coolant Refill Tool
    • J 42401 Radiator Pressure Adapter

Draining Procedure

    Caution: In order to avoid personal injury, do not remove the cap or open the cooling system drains from a hot system. Allow the system to cool first.


    Object Number: 1922919  Size: SH

    Important: A 7.6 liter (8 qt) coolant container will be needed.

  1. Place the coolant container under the radiator drain cock located at the bottom of the right radiator end tank.
  2. Open the drain cock and drain the coolant. A small amount of coolant will drain from the system.

  3. Object Number: 1922923  Size: SH
  4. Remove the surge tank cap from the surge tank and the coolant will drain from the system.

  5. Object Number: 964352  Size: SH
  6. For LE5 and LAT vehicles, if the engine block needs to be drained, a drain bolt is located near the bottom of the water pump assembly.
  7. Inspect the coolant.
  8. Follow the appropriate procedure based on the condition of the coolant.
  9. • Normal in appearance--Follow the filling procedure.
    • Discolored--Follow the flush procedure. Refer to Coolant System Flushing .

Vac-N-Fill Procedure

    Caution: To avoid being burned, do not remove the radiator cap or surge tank cap while the engine is hot. The cooling system will release scalding fluid and steam under pressure if radiator cap or surge tank cap is removed while the engine and radiator are still hot.

    Important: To prevent boiling of the coolant/water mixture in the vehicle’s cooling system, do not apply vacuum to a cooling system above 49°C (120°F). The tool will not operate properly when the coolant is boiling.


    Object Number: 1617435  Size: SH
  1. Install J 42401-2 into the surge tank fill neck.
  2. Install J 42401-3 to the surge tank fill neck.
  3. Attach the Vac N Fill cap to the J 42401-3.

  4. Object Number: 1617436  Size: SH
  5. Attach the vacuum gage assembly to the Vac N Fill cap.

  6. Object Number: 1617437  Size: SH
  7. Attach the fill hose to the barb fitting on the vacuum gage assembly.
  8. Ensure that the valve is closed.


    Object Number: 1617438  Size: SH

    Important: Use a 50/50 mixture of DEX-COOL antifreeze and clean, drinkable water.

    Always use more coolant than necessary. This will eliminate air from being drawn into the cooling system.

  9. Pour the coolant mixture into the graduated reservoir.
  10. Place the fill hose in the graduated reservoir.
  11. Important: Prior to installing the vacuum tank onto the graduated reservoir, ensure that the drain valve located on the bottom of the tank is closed.

  12. Install the vacuum tank on the graduated reservoir with the fill hose routed through the cut-out area in the vacuum tank.

  13. Object Number: 1617439  Size: SH
  14. Attach the venturi assembly to the vacuum tank.

  15. Object Number: 1617440  Size: SH
  16. Attach a shop air hose to the venturi assembly.
  17. Ensure the valve on the venturi assembly is closed.


    Object Number: 1617441  Size: SH
  18. Attach the vacuum hose to the vacuum gage assembly and the vacuum tank.

  19. Object Number: 1617442  Size: SH
  20. Open the valve on the venturi assembly. The vacuum gage will begin to rise and a hissing noise will be present.

  21. Object Number: 1617443  Size: SH
  22. Continue to draw vacuum until the needle stops rising. This should be 610-660 mm Hg (24-26 in Hg).
  23. Cooling hoses may start to collapse. This is normal due to vacuum draw.

  24. To aid in the fill process, position the graduated reservoir above the surge tank.

  25. Object Number: 1617446  Size: SH
  26. Slowly open the valve on the vacuum gage assembly. When the coolant reaches the top of the fill hose, close the valve. This will eliminate air from the fill hose.
  27. Close the valve on the venturi assembly.
  28. If there is a suspected leak in the cooling system, allow the system to stabilize under vacuum and monitor for vacuum loss.
  29. If vacuum loss is observed, refer to Loss of Coolant .

  30. Open the valve on the vacuum gage assembly. The vacuum gage will drop as coolant is drawn into the system.

  31. Object Number: 1617448  Size: SH
  32. Once the vacuum gage reaches zero, close the valve on the vacuum gage assembly and repeat steps 12-18.

  33. Object Number: 1617450  Size: SH
  34. Detach the Vac N Fill cap from the J 42401-3.
  35. Remove J 42401-2 from the surge tank fill neck.
  36. Add coolant to the system as necessary.
  37. Inspect the concentration of the coolant mixture using J 26568 .
  38. Important: After filling the cooling system, the extraction hose can be used to remove excess coolant to achieve the proper coolant level.

  39. Detach the vacuum hose from the vacuum gage assembly.
  40. Attach the extraction hose to the vacuum hose.

  41. Object Number: 1617453  Size: SH
  42. Open the valve on the venturi assembly to start a vacuum draw.

  43. Object Number: 1617456  Size: SH
  44. Use the extraction hose to draw out coolant to the proper level.
  45. The vacuum tank has a drain valve on the bottom of the tank. Open the valve to drain coolant from the vacuum tank into a suitable container for disposal.