Special Tools
EN-48932
Hydraulic Belt Tensioner Compressor
Removal Procedure
- Remove the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.
- Install the
EN-48932
(1) to the drive belt tensioner spring.
- Compress the drive belt tensioner spring fully using the
EN-48932
(1).
- Remove the tensioner spring bolts (1) from the tensioner.
- Remove the tensioner spring from the tensioner.
- Remove the drive belt from under the middle idler pulley.
- Remove the drive belt from the vehicle.
Installation Procedure
- Install and position the drive belt around all of the pulleys except for the middle idler pulley.
- Install the tensioner spring on the tensioner.
Notice: Refer to Fastener Notice in the Preface section.
- Install the tensioner spring bolts (1) to the tensioner.
Tighten
Tighten the bolts to 22 N·m (16 lb ft).
- Install the drive belt under the middle idler pulley.
- Loosen the forcing bolt on the
EN-48932
(1) and remove from the drive belt tensioner spring.
- Install and position the drive belt around all of the pulleys except for the middle idler pulley.
- Ensure that the drive belt tensioner idler is fully seated against the drive belt.
- Install the air cleaner assembly. Refer to
Air Cleaner Assembly Replacement
.