• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors to detect if the motor generator temperature sensor is shorted to ground, shorted to voltage or open.
The engine is running.
Sensor output voltage less than 0.2 volt for 1 second
Sensor output voltage greater than 3.95 volts for 1 second
50 percent maximum torque limit
Normal range for 10 seconds
Possible temperature sensor short to ground.
Possible temperature sensor short to voltage or open.
Hybrid Controls Connector End Views
Caution: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.
⇒ | If within specified range, replace the SGCM. |
⇒ | If greater than the specified value, repair the open/high resistance. |
⇒ | If greater than the specified value, repair the open/high resistance. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for SGCM replacement, setup and programming |
• | Generator with Starter Replacement for MGU replacement |