• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Hood Ajar Switch Signal | P254F | P254F | P254F | -- |
Hood Closed Switch Signal | P254F | P254F | P254F | -- |
Ground | -- | P254F | -- | -- |
The starter/generator control module (SGCM) monitors the voltage input of the hood open switch signal circuit and the hood open closed switch signal circuit. With the hood open, the hood ajar portion of the switch is closed, grounding the hood ajar switch signal circuit from the ECM, and the hood closed portion of the switch is open. With the hood closed, the hood closed portion of the switch is closed, grounding the hood closed switch signal circuit from the SGCM, and the hood ajar portion of the switch is open. During proper operation, the two separate voltage signals at the SGCM should never be at the same voltage.
The hood ajar switch status is also sent to the engine control module (ECM) via serial data.
The SGCM continuously monitors for this DTC
Both the hood open switch signal circuit and the hood closed switch signal circuit are simultaneously in an active or inactive state.
Auto-start and auto-stop operation will be disabled.
• | A current DTC will clear when the conditions for setting are no longer present. |
• | A history DTC will clear after 40 malfunction free ignition cycles. |
Keyless Entry System Description and Operation
Control Module References for scan tool information
Ignition ON, observe the scan tool SGCM Hood Position parameter. With the hood open, the Hood Position parameter should read Open. With the hood closed, the Hood Position parameter should read Closed.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the SGCM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the SGCM. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the SGCM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the SGCM. |
⇒ | If the parameter does not change between the specified values, test or replace the hood ajar switch. |
⇒ | If the parameter does not change between the specified values, replace the ECM. |
⇒ | If not the specified value, replace the hood ajar switch. |
⇒ | If greater than the specified range, replace the hood ajar switch. |
⇒ | If not the specified value, replace the hood ajar switch. |
⇒ | If greater than the specified range, replace the hood ajar switch. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM or SGCM replacement, programming, and setup |