• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Hood Ajar Switch Signal | B3006 5A | B3006 5A | B3006 5A | -- |
Hood Closed Switch Signal | B3006 5A | B3006 5A | B3006 5A | -- |
Ground | -- | B3006 5A | -- | -- |
The body control module (BCM) monitors the voltage input of the hood open switch signal circuit and the hood open closed switch signal circuit. With the hood open, the hood ajar portion of the switch is closed, grounding the hood ajar switch signal circuit from the BCM, and the hood closed portion of the switch is open. With the hood closed, the hood closed portion of the switch is closed, grounding the hood closed switch signal circuit from the BCM, and the hood ajar portion of the switch is open. During proper operation, the two separate voltage signals at the BCM should never be at the same voltage.
The BCM continuously monitors for this DTC
Both the hood open switch signal circuit and the hood closed switch signal circuit are simultaneously in an active or inactive state.
• | Remote start functions will be disabled. |
• | The hood ajar switch inputs will be ignored by content theft deterrent (CTD). |
• | A current DTC will clear when the conditions for setting are no longer present. |
• | A history DTC will clear after 40 malfunction free ignition cycles. |
Keyless Entry System Description and Operation
Control Module References for scan tool information
Ignition ON, observe the scan tool BCM Hood Open Switch and Hood Closed Switch parameters. With the hood open, the Hood Open Switch parameter should read Active and the Hood Closed Switch parameter should read Inactive. With the hood closed, the Hood Open Switch parameter should read Inactive and the Hood Closed Switch parameter should read Active.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the signal circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If less than the specified range, test the signal circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If not the specified value, replace the hood ajar switch. |
⇒ | If greater than the specified range, replace the hood ajar switch. |
⇒ | If not the specified value, replace the hood ajar switch. |
⇒ | If greater than the specified range, replace the hood ajar switch. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, programming and setup |