Diagnostic Instructions
DTC Descriptor
DTC U0074 00: Control Module Communication Bus B Off
Diagnostic Fault Information
Circuit
| Short to Ground
| Open/High Resistance
| Short to Voltage
| Signal Performance
|
PTLAN +
| U0074*
| U189A* **
| U0074*
| --
|
PTLAN -
| U0074*
| U189A* **
| U0074*
| --
|
* Other modules/DTCs will set with this fault.
** An open between the on either PTLAN circuit may also cause a DTC U0074.
|
Circuit/System Description
The PTLAN serial data circuits are serial data buses used to communicate information between the control modules. The PTLAN serial data circuits also connect directly to the data link connector (DLC) for programming purposes. If this serial data system
is inoperative the modules will still communicate with the scan tool due to other serial data systems but not with each other. Communication with the scan tool for the modules on the PTLAN bus is through the serial data gateway module (SDGM) on the HSGMLAN serial
data system.
Conditions for Running the DTCs
• | Supply voltage to the modules are in the normal operating range. |
• | The ignition switch in any position other than START. |
Conditions for Setting the DTC
The module setting the DTC has attempted to establish communications on the PTLAN serial data circuits more than 3 times.
Action Taken When the DTCs Sets
• | The module suspends all message transmission. |
• | The MIL and battery indicators will illuminate, along with several DIC messages. |
• | The vehicle may continue to run for several minutes, then will stall and not start. |
Conditions for Clearing the DTC
• | A current DTC clears when the malfunction is no longer present. |
• | A history DTC clears when the module ignition cycle counter reaches the reset threshold, without a repeat of the malfunction. |
Diagnostic Aids
• | Circuits to the HPCM are diagnosed only to the PIM connector because the HPCM is replaced as part of the PIM. |
• | Different DTCs may set in different modules along with this DTC depending on where the fault occurs and the vehicle operating conditions when the fault occurs. |
Reference Information
Schematic Reference
Connector End View Reference
Component Connector End Views
Description and Operation
Data Link Communications Description and Operation
Electrical Information Reference
Circuit/System Testing
Initial Test
- Ignition ON, verify 4-6 volts between the PTLAN circuits of the DLC connector terminals 3 and 11.
⇒ | If not within the specified range, refer to Active U0074 Test. |
- Verify that DTC U18xx is not set in any module listed.
Active U0074 Test
- With the ignition OFF, disconnect the module/component harness connectors listed below one at a time. After each disconnect and with the ignition ON, test for 4-6 volts between PTLAN circuits of DLC connector terminals 3 and 11 until the voltage
is within specified range.
1.1. | Data link resistor 2 - X1 |
1.2. | Yaw rate and lateral acceleration sensor - X1 |
1.3. | Engine control module (ECM) - X2 |
1.4. | Hybrid powertrain control module (HPCM) - X1 |
1.5. | Accessory DC power control module (APM) - X1 |
1.6. | Electronic brake control module (EBCM) - X1 |
1.7. | Serial data gateway module (SDGM) - X1 |
⇒ | If all module/components are disconnected and not within the specified range, test all 4 PTLAN circuits of SDGM connector X1 for a short between them, short to voltage, or a short to ground. If the circuits test normal, replace the SDGM. |
Important: If either the data link resistor or the ECM is the module/component disconnected before voltage at the DLC terminals is within the specified range no further testing is necessary, replace the last module/component disconnected.
- Test for infinite resistance between both PTLAN circuits of the last module disconnected that lead to the previously disconnected module/component.
⇒ | If less than the specified value, test the circuits for a short together. |
- Test for infinite resistance between ground and both PTLAN circuits of the last module disconnected that lead to the previously disconnected module/component.
⇒ | If less than the specified value, test the circuit for a short to ground. |
- Test for less than 1 volt between ground and both PTLAN circuits of the last module disconnected that lead to the previously disconnected module/component.
⇒ | If greater than the specified range, test the circuit for a short to voltage. |
- If the circuits test normal, replace the last module disconnected.
Repair Instructions
Perform the