GM Service Manual Online
For 1990-2009 cars only
Table 1: SGCM to MGU Terminal Reference Table
Table 2: MGU to SGCM Specification Table
Table 3: SGCM to MGU Specification Table

Diagnostic Instructions

    • Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    • Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptor

DTC P0A4C: Starter/Generator Position Sensor Performance

Circuit/System Description

The starter/generator control module (SGCM) monitors the motor generator unit (MGU) angle position sensor circuit. to detect a fault in the angle data.

Conditions for Running the DTC

The engine is running.

Conditions for Setting the DTC

(Data error) R/D IC angle data does not match with micro computer angle data. Self check fault when initial sequence (initialization error).

Action Taken When the DTC Sets

Stop PWM (MGU shutdown)

Conditions for Clearing the DTC

Clears 30 seconds after cycle wakeup signal.

Diagnostic Aids

Possible electrical failure at RD circuit

Reference Information

Schematic Reference

Hybrid Controls Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Starter/Generator Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Circuit/System Testing

  1. Disconnect the MGU X2 and the SGCM X2 connectors. Refer to Generator with Starter Replacement and Generator Control Module Replacement.
  2. Test the circuits in the SGCM to MGU Terminal Reference Table as indicated below. Also test these circuits for short to ground.
  3. If any of the circuits are not within specification, repair the open/high resistance or short to ground.
  4. Reconnect MGU connector X2.
  5. Test the circuits in the MGU to SGCM Specification Table to ground as indicated below.
  6. If all circuits test normal, replace the MGU.
  7. Reconnect the MGU X2 connector and disconnect the SGCM X2 connector. Refer to Generator with Starter Replacement and Generator Control Module Replacement.
  8. Test the circuits in the SGCM to MGU Specification Table as indicated below.
  9. If any of the circuits are not within the specified range, replace the SGCM.

SGCM to MGU Terminal Reference Table

MGU Connector/Terminal

SCGM Connector/Terminal

Minimum Resistance

Maximum Resistance

Harness Continuity Test

B

X2/7

--

less than 1 ohm

C

X2/6

--

less than 1 ohm

D

X2/4

--

less than 1 ohm

E

X2/17

--

less than 1 ohm

F

X2/20

--

less than 1 ohm

G

X2/19

--

less than 1 ohm

H

X2/5

--

less than 1 ohm


MGU to SGCM Specification Table

MGU Connector/Terminal

Signal Name

Minimum Resistance

Maximum Resistance

Measurements made to ground. SGCM disconnected and MGU connected.

D

REZ-

1.6k ohms

2k ohms

H

REZ+

1.6k ohms

2k ohms

C

REZ3

Over 1 M ohm

--

B

REZ4

Over 1 M ohm

--

E

REZGS (GND)

--

less than 5 ohm

G

REZ1

Over 1 M ohm

--

F

X2/5

Over 1 M ohm

--


SGCM to MGU Specification Table

SGCM Connector/Terminal

SGCM Connector/Terminal

Minimum Resistance

Maximum Resistance

MGU disconnected and SGCM connected.

X2/4

X2/5

20.1 ohms

26.7 ohms

X2/6

X2/19

32.4 ohms

43.0 ohms

X2/7

X2/20

32.9 ohms

43.5 ohms

X2/4

X2/6

Over 1 M ohm

--

X2/4

X2/7

Over 1 M ohm

--

X2/6

X2/7

Over 1 M ohm

--

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Generator with Starter Replacement
    •  Control Module References for SGCM replacement, setup, and programming