Table 1: | SGCM to MGU Terminal Reference Table |
Table 2: | MGU to SGCM Specification Table |
Table 3: | SGCM to MGU Specification Table |
• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors the motor generator unit (MGU) angle position sensor circuit. to detect a fault in the angle data.
The engine is running.
(Data error) R/D IC angle data does not match with micro computer angle data. Self check fault when initial sequence (initialization error).
Stop PWM (MGU shutdown)
Clears 30 seconds after cycle wakeup signal.
Possible electrical failure at RD circuit
Starter/Generator Description and Operation
Control Module References for scan tool information
⇒ | If any of the circuits are not within specification, repair the open/high resistance or short to ground. |
⇒ | If all circuits test normal, replace the MGU. |
⇒ | If any of the circuits are not within the specified range, replace the SGCM. |
MGU Connector/Terminal | SCGM Connector/Terminal | Minimum Resistance | Maximum Resistance |
---|---|---|---|
Harness Continuity Test | |||
B | X2/7 | -- | less than 1 ohm |
C | X2/6 | -- | less than 1 ohm |
D | X2/4 | -- | less than 1 ohm |
E | X2/17 | -- | less than 1 ohm |
F | X2/20 | -- | less than 1 ohm |
G | X2/19 | -- | less than 1 ohm |
H | X2/5 | -- | less than 1 ohm |
MGU Connector/Terminal | Signal Name | Minimum Resistance | Maximum Resistance |
---|---|---|---|
Measurements made to ground. SGCM disconnected and MGU connected. | |||
D | REZ- | 1.6k ohms | 2k ohms |
H | REZ+ | 1.6k ohms | 2k ohms |
C | REZ3 | Over 1 M ohm | -- |
B | REZ4 | Over 1 M ohm | -- |
E | REZGS (GND) | -- | less than 5 ohm |
G | REZ1 | Over 1 M ohm | -- |
F | X2/5 | Over 1 M ohm | -- |
SGCM Connector/Terminal | SGCM Connector/Terminal | Minimum Resistance | Maximum Resistance |
---|---|---|---|
MGU disconnected and SGCM connected. | |||
X2/4 | X2/5 | 20.1 ohms | 26.7 ohms |
X2/6 | X2/19 | 32.4 ohms | 43.0 ohms |
X2/7 | X2/20 | 32.9 ohms | 43.5 ohms |
X2/4 | X2/6 | Over 1 M ohm | -- |
X2/4 | X2/7 | Over 1 M ohm | -- |
X2/6 | X2/7 | Over 1 M ohm | -- |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for SGCM replacement, setup, and programming |