• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors to detect internal faults. If a fault is detected, the appropriate DTC will set.
The engine is running.
The gate driver voltage fault signal is low or PWM logic error fault signal is low.
RAM check error
RAM check error (calculated ROMSUM value does not match with defined value).
5 volt reference fault, 5 volt input AD value (2 byte) is out of the range for 100 ms.
• | Stop PWM (MGU shutdown) |
• | APM PWM Off |
Clears 30 seconds after cycle wake up signal.
Possible internal electrical failure of the SGCM.
Starter/Generator Description and Operation
Control Module References for scan tool information
⇒ | If the DTC resets, replace the SGCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming