• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
The starter/generator control module (SGCM) monitors the performance to detect 12-volt DC wire electrical failure by comparing the 12-volt input to the 12-volt output values. If the difference is greater than 5 volts, the DTC sets.
• | The engine is running. |
• | Hybrid mode is active. |
The 12-volt power supply -- 12-volt output voltage is greater than 5 volts for 119 ms and any fault during 15 seconds wait period.
• | Stop PWM (MGU shutdown). |
• | APM PWM off. |
Cycle wake up signal.
Possible 12-volt battery or APM voltage sensor stuck.
Starter/Generator Description and Operation
Control Module References for scan tool information
⇒ | If the DTC resets, replace the SGCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
Control Module References for SGCM replacement, setup, and programming