GM Service Manual Online
For 1990-2009 cars only

Diagnostic Instructions

    •  Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
    •  Review Strategy Based Diagnosis for an overview of the diagnostic approach.
    •  Diagnostic Procedure Instructions provides an overview of each diagnostic category.

DTC Descriptors

DTC P0ABC: Hybrid Battery Voltage Sensor Circuit Low Voltage

DTC P0ABD: Hybrid Battery Voltage Sensor Circuit High Voltage

Circuit/System Description

The battery energy control module (BECM) monitors the hybrid system voltage using the internal voltage sensor, this DTC sets when the sensor voltage is not within the calibrated range.

Conditions for Running the DTC

The engine is running.

Conditions for Setting the DTC

P0ABC

Pack Voltage raw A/D less than 0.5 volt

P0ABD

Pack Voltage raw A/D greater than 4.5 volts

Action Taken When the DTC Sets

Hybrid system is inactive.

Conditions for Clearing the DTC

Pack voltage operates inside the threshold range.

Reference Information

Schematic Reference

Hybrid Energy Storage Schematics

Connector End View Reference

Component Connector End Views

Description and Operation

Generator Battery Carrier Description and Operation

Electrical Information Reference

    •  Circuit Testing
    •  Connector Repairs
    •  Testing for Intermittent Conditions and Poor Connections
    •  Wiring Repairs

Scan Tool Reference

Control Module References for scan tool information

Special Tools

J 35616 GM Approved Terminal Test Kit

Circuit/System Testing

Warning: To help avoid personal injury, be careful when working in the vicinity of the generator battery disconnect control module. Internal components will still be live, 36V potential, even when the cover has been opened or removed.

Warning: To help avoid personal injury, additional precautions must be taken prior to working on the generator control module or the generator starter. After removing the 36V battery cables from the generator battery, remove both engine wiring harness connectors from the generator control module. Wait at least 5 minutes and then remove the generator control module cover. Verify voltage levels at all 36V, 12V, and 3-phase connections, are less than 3 volts using a DMM before proceeding.

Important: Use the following list to identify the appropriate terminals to test:

    • J-35616-65B for female terminals
    • J-35616-64B for male terminals

P0ABC

  1. Verify DTC P0ABC is set as current.
  2. Disconnect harness connector X1 from the BECM. Refer to Hybrid Battery Service Disconnect/Connect.
  3. Test for less than 6.5 volts between X1 terminal 1 and terminal  12.
  4. If greater than the specified range, replace the BECM.
  5. Test for 1.3-1.7k ohms between X1 terminal 1 and Generator Battery 1- X1.
  6. If not within the specified range, replace the harness assembly.
  7. Test for 1.3-1.7k ohms between X1 terminal 12 and Generator Battery 3- X2.
  8. If not within the specified range, replace the harness assembly.

P0ABD

  1. Verify DTC P0ABD is set as current.
  2. Disconnect harness connector X1 from the BECM. Refer to Hybrid Battery Service Disconnect/Connect.
  3. Test for less than 58.5 volts between terminal 1 and terminal 12.
  4. If greater than the specified range, replace the BECM.
  5. Test for 1.3-1.7k ohms between X1 terminal 1 and Generator Battery 1- X1.
  6. If not within the specified range, replace the harness assembly.
  7. Test for 1.3-1.7k ohms between X1 terminal 12 and Generator Battery 3- X2.
  8. If not within the specified range, replace the harness assembly.

Repair Instructions

Perform the Diagnostic Repair Verification after completing the diagnostic procedure.

    •  Generator Battery Temperature Sensor Wiring Harness Replacement
    •  Control Module References for BECM replacement, setup, and programming