🢒 Generator Control Module Coolant Inlet Hose Replacement
Special Tools
J 38185
Hose Clamp Pliers
Removal Procedure
Drain the generator control module cooling system. Refer to
Generator Control Module Cooling System Draining and Filling
Remove the drive motor power inverter module brace. Refer to
Drive Motor Generator Power Inverter Module Brace Replacement
Remove the left headlamp. Refer to
Headlamp Replacement
Remove the radiator opening upper cover. Refer to
Radiator Opening Upper Cover Replacement
Disconnect the generator control module coolant inlet hose quick connect fitting (1).
Remove the generator control module coolant inlet hose (2) from the generator control module.
Using
J 38185
Hose Clamp Pliers reposition the generator control module coolant inlet hose clamp (1).
Remove the generator control module coolant inlet hose (2) from the radiator.
Remove the generator control module coolant inlet hose from the vehicle.
Installation Procedure
Install the generator control module coolant inlet hose to the vehicle.
Install the generator control module coolant inlet hose (2) to the radiator.
Using
J 38185
Hose Clamp Pliers reposition the generator control module coolant inlet hose clamp (1).
Install the generator control module coolant inlet hose (2) to the generator control module and connect the quick connect fitting (1).
Install the radiator opening upper cover. Refer to
Radiator Opening Upper Cover Replacement
Install the left headlamp. Refer to
Headlamp Replacement
Install the drive motor power inverter module brace. Refer to
Drive Motor Generator Power Inverter Module Brace Replacement
Fill the generator control module cooling system. Refer to