• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
HO2S Bank 1 Sensor 1 Signal | P0131 | P0134, P0135 | P0132 | P0133, P2096, P2097 |
HO2S Bank 1 Sensor 2 Signal | P0137 | P0140 | P0138 | P0140 |
HO2S Bank 2 Sensor 1 Signal | P0151 | P0154, P0155 | P0152 | P0153, P2098, P2099 |
HO2S Bank 2 Sensor 2 Signal | P0157 | P0160 | P0158 | P0160 |
Low Reference | -- | P0134, P0135, P0154, P0155 | -- | -- |
Circuit | Short to Ground | Open | Short to Voltage |
---|---|---|---|
Operating Conditions: Engine operating in Closed Loop. Parameter Normal Range: Fluctuates above and below 350-500 mV. | |||
Sensor Signal | 0-60 mV | 400-455 mV | 1275 mV |
Low Reference | -- | 400-455 mV | 1275 mV |
The heated oxygen sensors (HO2S) are used for fuel control and catalyst monitoring. Each HO2S compares the oxygen content of the surrounding air with the oxygen content of the exhaust stream. When the engine is started, the control module operates in an Open Loop mode, ignoring the HO2S signal voltage while calculating the air-to-fuel ratio. The control module supplies the HO2S with a reference, or bias voltage of about 450 mV. While the engine runs, the HO2S heats up and begins to generate a voltage within a range of 0-1,000 mV. This voltage will fluctuate above and below the bias voltage. Once sufficient HO2S voltage fluctuation is observed by the control module, Closed Loop is entered. The control module uses the HO2S voltage to determine the air-to-fuel ratio. An HO2S voltage that increases above bias voltage toward 1,000 mV indicates a rich fuel mixture. An HO2S voltage that decreases below bias voltage toward 0 mV indicates a lean fuel mixture.
The heating elements inside each HO2S heat the sensor to bring the sensor up to operating conditions faster. This allows the system to enter Closed Loop earlier and the control module to calculate the air-to-fuel ratio sooner.
• | DTCs P0117, P0118, P0125, and P0128 are not set. |
• | The HO2S heater is at operating temperature. |
• | The engine is operating for greater than 1 second. |
• | The ignition voltage is more than 10.5 volts. |
• | The engine coolant temperature is less than 40°C (104°F) at start-up and the engine coolant temperature was more than 60°C (140°F) when the ignition was turned OFF last ignition cycle. |
• | The calculated exhaust temperature is between 250-800°C (482-1,472°F) for more than 90 seconds. |
• | DTCs P0137 and P0157 run continuously once the above conditions are met. |
• | The HO2S heater is at operating temperature. |
• | The engine is operating for greater than 1 second. |
• | The ignition voltage is more than 10.5 volts. |
• | The calculated exhaust temperature is between 250-800°C (482-1,472°F) for more than 90 seconds. |
• | DTCs P0138 and P0158 run continuously once the above conditions are met for greater than 5 seconds. |
• | DTCs P0140 and P0160 run continuously once the above conditions are met for greater than 60 seconds. |
The ECM detects that a secondary HO2S signal voltage is less than 60 mV for greater than 4 seconds of for a cumulative of 50 seconds.
The ECM detects that the HO2S signal voltage is more than 1,080 mV for greater than 4 seconds or for a cumulative of 50 seconds.
• | The ECM detects that the HO2S voltage is between 401-519 mV . |
• | The ECM detects that the measured internal resistance of the HO2S is greater than 40,000 ohms, when the calculated exhaust temperature is greater than 600°C (1,112°F). |
• | Either condition exists for greater than 4 seconds or for a cumulative of 50 seconds. |
DTCs P0137, P0138, P0140, P0157, P0158, and P0160 are Type B DTCs.
DTCs P0137, P0138, P0140, P0157, P0158, and P0160 are Type B DTCs.
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
⇒ | If less than the specified value, test the signal circuit for a short to ground. If the circuit/connections test normal, replace the ECM. |
⇒ | If greater than the specified value, test the signal circuit for a short to voltage. If the circuit/connections test normal, replace the ECM. |
⇒ | If greater than the specified value, test the signal circuit for an open/high resistance. If the circuit/connections test normal, replace the ECM. |
⇒ | If greater than the specified value, test the low reference circuit for an open/high resistance or for a short to voltage. If the circuit/connections test normal, replace the ECM. |
• | Lean, rich, or leaking fuel injectors--Refer to Fuel Injector Balance Test with Special Tool or Fuel Injector Balance Test with Tech 2 . |
• | A fuel pressure that is too low or too high--Refer to Fuel System Diagnosis . |
• | Fuel that is contaminated--Refer to Alcohol/Contaminants-in-Fuel Diagnosis . |
• | Evidence of water intrusion into the electrical connector of the HO2S |
• | The HO2S is loose |
• | Exhaust leaks near the HO2S |
• | Engine vacuum leaks |
⇒ | If you find any of the above conditions, repair as necessary. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for engine control module replacement, setup, and programming |