Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature | Maximum Left Rear Discharge Air Temperature |
---|---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 172-275 kPa (25-40 psi) | 1419-1770 kPa (206-257 psi) | 12°C (52°F) | 13°C (55°F) |
19-24°C (66-75°F) | Below 40% | 192-289 kPa (28-42 psi) | 1564-1812 kPa (227-263 psi) | 13°C (55°F) | 15°C (59°F) |
Above 40% | 199-296 kPa (29-43 psi) | 1419-1694 kPa (206-246 psi) | 15°C (59°F) | 18°C (63°F) | |
25-29°C (76-85°F) | Below 35% | 206-303 kPa (30-44 psi) | 1564-1812 kPa (227-263 psi) | 17°C (61°F) | 18°C (64°F) |
35-60% | 241-337 kPa (35-49 psi) | 1591-1915 kPa (231-278 psi) | 18°C (63°F) | 19°C (66°F) | |
Above 60% | 248-344 kPa (36-50 psi) | 1632-1922 kPa (237-279 psi) | 18°C (63°F) | 20°C (68°F) | |
30-35°C (86-95°F) | Below 30% | 268-372 kPa (39-54 psi) | 1839-2156 kPa (267-313 psi) | 19°C (66°F) | 23°C (72°F) |
30-50% | 196-399 kPa (43-58 psi) | 1674-1949 kPa (243-283 psi) | 20°C (68°F) | 23°C (73°F) | |
Above 50% | 275-385 kPa (40-56 psi) | 1722-2060 kPa (250-299 psi) | 23°C (72°F) | 25°C (77°F) | |
36-41°C (96-105°F) | Below 20% | 289-378 kPa (42-55 psi) | 1750-1956 kPa (254-284 psi) | 23°C (72°F) | 25°C (77°F) |
20-40% | 296-399 kPa (43-58 psi) | 1880-2777 kPa (273-316 psi) | 23°C (73°F) | 27°C (79°F) | |
Above 40% | 323-427 kPa (47-62 psi) | 1956-2204 kPa (284-320 psi) | 24°C (75°F) | 28°C (82°F) | |
42-46°C (106-115°F) | Below 20% | 358-461 kPa (52-67 psi) | 2177-2411 kPa (316-350 psi) | 25°C (77°F) | 29°C (84°F) |
Above 20% | 351-454 kPa (51-66 psi) | 2163-2404 kPa (314-349 psi) | 27°C (79°F) | 30°C (86°F) | |
47-49°C (116-120°F) | Below 30% | 399-502 kPa (58-73 psi) | 2439-2645 kPa (354-384 psi) | 29°C (84°F) | 32°C (88°F) |
Table 1: | A/C Performance Table |
This test measures the operating efficiency of the A/C system under the following conditions:
• | The current ambient air temperature |
• | The current relative humidity |
• | The high side pressure of the A/C system |
• | The low side pressure of the A/C system |
• | The temperature of the air being discharged into the passenger compartment |
The numbers below refer to the step numbers on the diagnostic table.
This step determines if the A/C system has at least the minimum refrigerant charge required to operate the system without damage.
This step measures the performance of the A/C system.
This step is to allow for vehicle variations as well as high ambient temperatures.
Step | Action | Values | Yes | No | ||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||||||||
Are both the low side and high side pressures within the specified value? | More than 16°C (60°F) - 345 kPa (50 psi) More than 24°C (75°F) - 483 kPa (70 psi) More than 33°C (90°F) - 690 kPa (100 psi) | Go to Step 2 | Go to Leak Testing | |||||||||||||||||||||||
Important: Record the relative humidity and the ambient air temperature at the time of the test.
Important: Press the RESET button, before using the print function of the J 43600 .
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 3 | |||||||||||||||||||||||
If the pressures and temperatures recorded do not fall within the specified ranges:
Does all the data recorded fall within the specified ranges of the A/C performance table? | -- | Go to Step 8 | Go to Step 4 | |||||||||||||||||||||||
4 | Do the high and low side pressures fall within the specified ranges, but the panel outlet temperatures do not? | -- | Go to Step 5 | |||||||||||||||||||||||
5 | Is the low side pressure greater than the specified range, but the high side pressure within or less than the specified range? | -- | Go to Step 6 | |||||||||||||||||||||||
6 | Are the low and high side pressures both greater than the specified ranges? | -- | Go to Step 7 | |||||||||||||||||||||||
7 | Is the high side pressure greater than the specified range, but the low side pressure is within or less than the specified range? | -- | Go to Step 8 | |||||||||||||||||||||||
8 | Operate the system in order to verify the test results. Did you find the same results? | -- | System OK |
Ambient Temperature | Relative Humidity | Low Side Service Port Pressure | High Side Service Port Pressure | Maximum Left Center Discharge Air Temperature |
---|---|---|---|---|
13-18°C (55-65°F) | 0-100% | 130-296 kPa (19-43 psi) | 876-1412 kPa (127-205 psi) | 8°C (46°F) |
19-24°C (66-75°F) | Below 40% | 144-303 kPa (21-44 psi) | 1129-1639 kPa (164-238 psi) | 12°C (52°F) |
Above 40% | 151-303 kPa (22-44 psi) | 1205-1688 kPa (175-245 psi) | 03°C (50°F) | |
25-29°C (76-85°F) | Below 35% | 151-303 kPa (22-44 psi) | 1334-1846 kPa (198-268 psi) | 13°C (54°F) |
35-60% | 179-282 kPa (26-41 psi) | 1646-1922 kPa (239-279 psi) | 13°C (54°F) | |
Above 50% | 179-282 kPa (26-41 psi) | 1667-1908 kPa (242-277 psi) | 12°C (52°F) | |
30-35°C (86-95°F) | Below 30% | 179-268 kPa (26-39 psi) | 1446-1701 kPa (210-247 psi) | 14°C (57°F) |
30-50% | 179-282 kPa (26-41 psi) | 1481-1694 kPa (215-246 psi) | 14°C (57°F) | |
Above 50% | 179-275 kPa (26-40psi) | 1416-1653 kPa (206-240 psi) | 13°C (55°F) | |
36-41°C (96-105°F) | Below 20% | 213-310 kPa (31-45 psi) | 1660-1887 kPa (241-274 psi) | 15°C (59°F) |
20-40% | 213-310 kPa (31-45 psi) | 1653-1908 kPa (240-277 psi) | 15°C (59°F) | |
Above 40% | 206-310 kPa (30-45 psi) | 1626-1853 kPa (236-269 psi) | 15°C (59°F) | |
42-46°C (106-115°F) | Below 20% | 234-337 kPa (34-49 psi) | 1825-2053 kPa (265-298 psi) | 18°C (63°F) |
Above 20% | 241-344 kPa (35-50 psi) | 1798-2046 kPa (261-297 psi) | 18°C (63°F) | |
47-49°C (116-120°F) | Below 30% | 254-351 kPa (37-51 psi) | 2004-2246 kPa (291-326 psi) | 18°C (64°F) |