Removal Procedure
- Disconnect the electrical connector from the blower motor control module.
- Remove the blower motor control module screws from the HVAC module.
- Remove the blower motor control module from the HVAC module.
Installation Procedure
- Install the blower motor control module to the HVAC module.
Caution: Refer to Fastener Caution in the Preface section.
- Install the blower motor control module screws to the HVAC module.
Tighten the screws to
1.5 N·m (13 lb in).
- Connect the electrical connector to the blower motor control module.