• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Reading Lamp Voltage Supply Circuit | 1 | 1 | -- | -- |
Reading Lamp Ground Supply Circuit | -- | 1 | 1 | -- |
Reading Lamp Assembly | 1, 2 | 1 | 1, 2 | -- |
1. Reading Lamp Inoperative 2. Reading Lamp Always ON |
When the roof rail reading lamps switches are in the OFF position, the body control module (BCM) supplies the roof rail reading lamps park lamps with voltage and ground. The BCM maintains voltage and ground for a set amount of time for the illuminated entry option. When the roof rail reading lamp switch is in the ON position the BCM only supplies the voltage for the roof rail lamps
A short to ground, a short to voltage or an open in the following location may cause a malfunction to occur:
• | The reading lamp switch supply circuit |
• | The reading lamp switch ground circuit |
• | The reading lamp switch |
Lighting Systems Connector End Views
Ignition ON, turn the reading lamps ON by turning the switch on the reading lamps to the ON position. The reading lamps should turn ON.
⇒ | If greater than 1.0 ohm, test the ON circuit for an open/high resistance. |
⇒ | If the test lamp does not turn ON, test the signal circuit of the reading lamp switch for a short to ground or an open/high resistance. |
⇒ | If greater than 2.0 ohms, replace the reading lamp assembly. |
⇒ | If the resistance is not within the specified range, replace the reading lamp bulb. |