• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Ignition Voltage | P0498 | P0449 | -- | -- |
EVAP Canister Vent Solenoid Valve Control Circuit | P0498 | P0449 | P0499 | -- |
The evaporative emission (EVAP) canister vent valve is used for EVAP system diagnostics. The EVAP canister vent valve is a normally open valve. Battery positive voltage is supplied directly to the EVAP canister vent valve. The engine control module (ECM) controls the solenoid by grounding the control circuit with a solid state device called a driver. The driver is equipped with a feedback circuit that is pulled-up to a voltage. The ECM can determine if the control circuit is open, shorted to ground, or shorted to a voltage by monitoring the feedback voltage.
• | The engine speed is greater than 80 RPM. |
• | The ignition voltage is between 10-18 volts. |
• | The ECM has commanded the EVAP canister vent valve ON and OFF at least once during the ignition cycle. |
• | The DTCs run continuously when the above conditions are met. |
The ECM detects the voltage on the EVAP canister vent valve control circuit is between 2.6-4.6 volts when the driver is commanded OFF. The condition exists for 4 seconds, or a cumulative of 30 seconds.
The ECM detects the voltage on the EVAP canister vent valve control circuit is less than 2.6 volts when the driver is commanded OFF. The condition exists for 4 seconds, or a cumulative of 30 seconds.
The ECM detects the voltage on the EVAP canister vent valve control circuit is greater than 4.6 volts when the driver is commanded ON. The condition exists for 4 seconds, or a cumulative of 30 seconds.
• | DTCs P0449, P0498 and P0499 are Type B DTCs. |
• | The EVAP system will only purge during Open Loop. |
DTCs P0449, P0498 and P0499 are Type B DTCs.
Evaporative Emission Control System Description
Powertrain Diagnostic Trouble Code (DTC) Type Definitions
Control Module References for scan tool information
Note: The ignition circuit supplies voltage to other components. Make sure you test all circuits for a short to ground, or test all components for being shorted that share the ignition circuit.
⇒ | If the test lamp does not illuminate, test the ignition voltage circuit for a short to ground or an open/high resistance. If the circuit tests normal and the ignition voltage circuit fuse is open, test all components connected to the ignition voltage circuit and replace as necessary. |
Note: The control circuit for the EVAP vent solenoid valve is pulled-up to voltage within the ECM, 2.6-4.6 volts on the control circuit is normal.
⇒ | If the test lamp remains ON all the time, test for a short to ground on the control circuit. If circuit/connections test normal, replace the ECM. |
⇒ | If the test lamp remains OFF all the time, test for a short to voltage or an open/high resistance on the control circuit. If circuit/connections test normal, replace the ECM. |
⇒ | If not within the specified range, replace the ECM. |
⇒ | If not within the specified range, replace the EVAP vent solenoid valve. |
⇒ | If less than the specified value, replace the EVAP vent solenoid valve. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for ECM replacement, setup, and programming |