Removal Procedure
Important: A NEW fuel tank module seal is necessary each time the fuel tank module is serviced. Obtain a NEW seal prior to beginning this service procedure.
Important: There are 2 fuel level sender unit and float assemblies in the fuel tank. There is 1 located on each fuel pump module. The fuel level sender unit and float is NOT the same for each of the fuel pump modules.
- Remove the fuel pump module . Refer to
Secondary Fuel Tank Module Replacement.
- Disconnect the fuel level sender unit and the float electrical connector.
- Release the retaining tabs and remove the level sensor by sliding up.
Installation Procedure
- Install the fuel level sender unit and float onto the fuel pump module. Make sure that the sender cap snaps into place.
- Connect the fuel level sender unit and the float electrical connector.
- Install the fuel pump module into the fuel tank. Refer to
Secondary Fuel Tank Module Replacement.