• | Perform the Diagnostic System Check - Vehicle prior to using this diagnostic procedure. |
• | Review Strategy Based Diagnosis for an overview of the diagnostic approach. |
• | Diagnostic Procedure Instructions provides an overview of each diagnostic category. |
Circuit | Short to Ground | Open/High Resistance | Short to Voltage | Signal Performance |
---|---|---|---|---|
Body Control Module (BCM) 4 Fuse B+ Supply | B2545 00 | B2545 00 | -- | -- |
Backup Lamps Control | B2545 00 | 1 | 1 | -- |
Backup Lamp - Left Ground | -- | 1 | -- | -- |
Backup Lamp - Right Ground | -- | 1 | -- | -- |
1. Backup Lamps Malfunction |
When the transmission is placed in the REVERSE position, the transmission control module (TCM) sends a serial data message to the body control module (BCM). The message indicates that the gear selector is in the REVERSE position. The BCM applies battery voltage to the backup lamps and inside rearview mirror. The backup lamps are permanently grounded at G402 for the left and G401 for the right. Once the driver moves the gear selector out of the REVERSE position, a message is sent by the TCM via serial data requesting the BCM to remove battery voltage from the backup lamp control circuit.
Battery voltage must be between 9-16 volts.
DTC B2545 00 will set when one of the following conditions exists:
• | The BCM detects a short to ground in the backup lamps control circuit. |
• | The BCM detects a short to ground or an open/high resistance in the BCM 4 fuse voltage supply circuit. |
When DTC B2545 00 is present, the backup lamps will not operate.
• | The condition responsible for setting the DTC no longer exists. |
• | A history DTC will clear once 100 consecutive malfunction-free ignition cycles have occurred. |
Exterior Lighting Systems Description and Operation
Control Module References for scan tool information
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, test the BCM 4 fuse B+ circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
⇒ | If the test lamp is always ON, test the control circuit for a short to voltage. If the circuit tests normal, replace the BCM. |
⇒ | If the test lamp is always OFF, test the control circuit for a short to ground or an open/high resistance. If the circuit tests normal, replace the BCM. |
Perform the Diagnostic Repair Verification after completing the diagnostic procedure.
• | Control Module References for BCM replacement, setup, and programming |