Removal Procedure
- Remove the left side insulator/closeout panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side.
- Disconnect the electrical connector from the mode actuator.
- Remove the mode actuator screws from the evaporator case assembly.
- Remove the mode actuator from the evaporator case assembly.
Installation Procedure
- Install the mode actuator to the evaporator case assembly.
Caution: Refer to Fastener Caution in the Preface section.
- Install the mode actuator screws to the evaporator case assembly.
Tighten the screws to
1.5 N·m (13 lb in).
- Connect the electrical connector to the mode actuator.
- Install the left side insulator/closeout panel. Refer to
Instrument Panel Insulator Panel Replacement - Left Side.
Note: Any time a mode actuator or the HVAC control module is replaced, the HVAC control module must be calibrated to ensure proper air distribution.
- Calibrate the actuators. Refer to
Actuator Recalibration.
- Cycle the ignition and verify proper operation.