🢒 Blower Motor Replacement
Removal Procedure
Remove the right sound insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
.
Disconnect the electrical connector from the blower motor.
Remove the blower motor screws from the HVAC module.
Remove the blower motor from the HVAC module.
Installation Procedure
Install the blower motor to the HVAC module.
Caution:
Refer to
Fastener Caution
in the Preface section.
Install the blower motor screws to the HVAC module.
Tighten the screws to
1.5 N·m (13 lb in).
Connect the electrical connector to the blower motor.
Install the right sound insulator panel. Refer to
Instrument Panel Insulator Panel Replacement - Right Side
.