Diagnostic Instructions
Circuit/System Description
When the A/C switch is pressed, the HVAC control module grounds the A/C request signal circuit. The body control module (BCM) receives the ground input and sends a GMLAN message to the engine control module (ECM) for an A/C request. This input will request
the ECM to ground the A/C compressor clutch relay control circuit, which will switch the A/C CLUTCH relay. With the relay contacts closed, battery voltage is supplied to the A/C compressor clutch assembly.
Diagnostic Aids
The following conditions must be met in order for the ECM to turn on the compressor clutch:
• | Battery voltage is between 9-16 volts |
• | Engine coolant temperature (ECT) is less than 123°C (253°F) |
• | Engine speed is less than 4760 RPM |
• | Engine speed is more than 600 RPM |
• | A/C high side pressure is between 2929-269 kPa (425-39 psi) |
• | Throttle position is less than 100 percent |
• | Evaporator temperature is greater than 0°C (32°F) |
• | ECM does not detect excessive torque load |
• | ECM does not detect insufficient idle quality |
Reference Information
Schematic Reference
HVAC Schematics
Connector End View Reference
Component Connector End Views
Description and Operation
Electrical Information Reference
Scan Tool Reference
Control Module References for Scan Tool Information
Circuit/System Testing
- Ignition OFF, disconnect the harness connector C1 at the HVAC control module.
- Test for less than 1.0 ohm of resistance between the ground circuit connector C1 and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Install a 3-amp fused jumper wire between the signal circuit terminal 63 connector C1 and ground. With a scan tool, verify the A/C Request Switch parameter is ON.
⇒ | If not On, test the signal circuit for a short to voltage or an open/high resistance. If circuit tests normal, replace the BCM. |
- Reconnect the harness connector of the HVAC control module. With a scan tool, verify the A/C Request Switch parameter cycles between On and Off with each press of the A/C switch.
⇒ | If the parameter does not cycle, test the signal circuit for a short to ground. If the circuit tests normal, test or replace the HVAC control module. |
- Remove the A/C compressor clutch relay.
- Verify that a test lamp illuminates between the relay coil B+ circuit and ground.
⇒ | If the test lamp does not illuminate, test the B+ circuit for a short to ground or an open/high resistance. |
- Verify that a test lamp illuminates between the relay switch B+ circuit and ground.
⇒ | If the test lamp does not illuminate, test the relay switch B+ circuit for an open/high resistance. If the A/C fuse is open, test the relay switch control circuit for a short to ground. If all circuits test normal, test or replace the A/C
compressor clutch. |
- Disconnect the harness connector terminal 1 at the A/C compressor clutch.
- Ignition OFF test for less than 1 ohm of resistance between the A/C compressor ground circuit and ground.
⇒ | If greater than the specified range, test the ground circuit for an open/high resistance. |
- Connect the harness connector at the A/C compressor clutch.
- Connect a 10-amp fused jumper wire between the relay switch B+ circuit and the relay switch control circuit. Verify the A/C compressor clutch engages.
⇒ | If the A/C compressor clutch does not activate, test the control circuit for an open/high resistance. If the circuit tests normal, test or replace the A/C compressor. |
- Connect a test lamp between the relay control circuit and the relay coil B+ circuit.
- Using a scan tool, command the A/C relay output ON and OFF. The test lamp should turn ON and OFF when changing between the commanded states.
⇒ | If the test lamp remains ON all the time, test for a short to ground on the control circuit. If the circuit tests normal, replace the ECM. |
⇒ | If the test lamp remains OFF all the time, test for a short to voltage or
an open/high resistance on the control circuit. If the circuit tests normal, replace the ECM. |
- If all circuits test normal, replace the A/C compressor.
Repair Instructions
Perform the
Diagnostic Repair Verification after completing the diagnostic procedure.