EL-39200 Digital Multimeter
For equivalent regional tools, refer to Special Tools.
Perform the following procedures while wiggling the harness from side to side. Continue this at convenient points (about 6 inches apart) while watching the test equipment.
If the fault is not identified, perform the procedure below using the MIN MAX feature on the EL-39200 DMM. This feature allows you to manipulate the circuit without having to watch the EL-39200. The EL-39200 will generate an audible tone when a change is detected.
Note: The EL-39200 must be used in order to perform the following procedure since the EL-39200 can monitor current, resistance or voltage while recording the minimum (MIN), and maximum (MAX) values measured.
Note: The 100 ms RECORD mode is the length of time an input must stay at a new value in order to record the full change.
• | If the variation between the recorded MIN and MAX voltage values is 1 V or greater an intermittent open or high resistance condition exists. Repair the condition as necessary. |
• | If the variation between the recorded MIN and MAX voltage values is less than 1 V, an intermittent open or high resistance condition does not exist. |