Step
| Action
| Normal Result(s)
| Abnormal Result(s)*
|
1
|
- Place the mirror select switch in the LH position.
- Operate the mirror control switch in the up and the down directions.
| The left
outside mirror moves smoothly upward and downward.
|
Power Mirror Inoperative - Left Side
|
2
| Operate the mirror control switch in the left and the right
directions.
| The left outside mirror moves smoothly to the left and to the right.
|
Power Mirror Inoperative - Left Side
|
3
|
- Place the mirror select switch in the RH position.
- Operate the mirror control switch in the up and the down directions.
| The right
outside mirror moves smoothly upward and downward.
|
|
4
| Operate
the mirror control switch in the left and the right directions.
| The right outside mirror
moves smoothly to the left and to the right.
|
|
5
|
- The following actions are to test the operation of the following:
• | The parasitic power control |
• | The courtesy lamp control |
• | The inadvertent power control outputs |
- Close the front doors.
- Engage the parking brake.
- Turn the ignition switch to the RUN position and perform the following
before 15 seconds pass:
4.1. | Open the right front door |
4.2. | Cycle the headlamp switch from OFF to PARK 3 times |
|
• | The interior lamps flash for approximately 1 minute. |
• | The multi-function alarm module returns to normal operation. |
|
Multifunction Alarm Module Replacement in Instrument
Panel, Gauges, and Console
|
* Refer to the appropriate symptom