Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Lighting Systems Diagnostic System Check? | -- | Go to Step 2 | |
2 | Do the right turn lamps operate properly? | -- | Go to Step 3 | Go to Turn Signal Lamps and Indicators Inoperative - One Side |
3 |
Does the scan tool indicate that the Right Turn Signal parameter is On? | -- | Go to Step 6 | Go to Step 4 |
4 | Test the right turn signal circuit for an open or high resistance between the instrument cluster (IPC) and the splice of the right turn signal circuit. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 5 |
5 | Inspect for poor connections at the harness connector of the instrument cluster (IPC). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 8 | Go to Step 6 |
6 |
Does the right turn indicator illuminate during the Display(s) Test? | -- | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 7 |
7 | Replace the instrument cluster (IPC). Refer to Instrument Cluster Replacement in Instrument Panel, Gauges and Console. Did you complete the repair? | -- | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |