Step | Action | Yes | No |
---|---|---|---|
SCHEMATIC REFERENCE: Cigar Lighter/Power Outlet Schematics | |||
1 | Did you perform the Cigar Lighter/Auxiliary Outlets Diagnostic System Check? | Go to Step 2 | Go to Diagnostic System Check - Cigar Lighter/Auxiliary Outlets |
2 | Operate the auxiliary outlet. Does the auxiliary outlet operate normally? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Does the front cigar lighter operate properly? | Go to Step 4 | |
4 | Inspect the AUX PWR fuse for an open. Is the fuse open? | Go to Step 8 | Go to Step 5 |
5 |
Does the test lamp illuminate? | Go to Step 7 | Go to Step 6 |
6 | Connect a test lamp between the supply voltage circuit of the auxiliary outlet and a good ground. Does the test lamp illuminate? | Go to Step 9 | Go to Step 10 |
7 | Inspect for a poor connection/terminal tension at the auxiliary. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 12 | Go to Step 11 |
8 | Repair a short to ground in the supply voltage circuit of the auxiliary outlet. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 12 | -- |
9 | Repair the open or high resistance in the ground circuit of the auxiliary outlet. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 12 | -- |
10 | Repair the open or high resistance in the supply voltage circuit of the auxiliary outlet. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | Go to Step 12 | -- |
11 | Replace the auxiliary outlet. Refer to 12-Volt Accessory Power Receptacle Replacement in Instrument Panel, Gauges, and Console. Did you complete the replacement? | Go to Step 12 | -- |
12 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |