Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||
1 | Did you perform the power door locks system check? | -- | Go to Step 2 | |
2 | Open the right front door while observing the interior lamps. Do the interior lamps turn on when you open the door? | -- | Go to Step 3 | |
3 |
Do the interior lamps light? | -- | Go to Step 4 | Go to Step 5 |
4 | Replace the remote control door lock receiver. Refer to Receiver Replacement . Did you complete the repair? | -- | -- | |
5 | Repair an open in CKT 395 between the remote control door lock receiver terminal S and S305. Refer to Wiring Repairs in Wiring Systems. Did you complete the repair? | -- | -- |