Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Inspect the control cables from the heater control unit to the heater case and to the blower case for proper routing, kinks, and interference. Do any of the control cables have improper routing, kinks, and/or interference? | -- | Go to Step 6 | Go to Step 2 |
2 |
Does the door bind? | -- | Go to Step 4 | Go to Step 3 |
3 | Inspect for control binding. Does the control bind? | -- | Go to Step 5 | Go to Step 11 |
4 |
Is the door seal OK? | -- | Go to Step 8 | Go to Step 7 |
5 |
Does the control cable bind? | -- | Go to Step 9 | Go to Step 10 |
6 |
Is the repair complete? | -- | Go to Step 12 | -- |
7 | Repair the door seal as necessary. Is the repair complete? | -- | Go to Step 12 | -- |
8 |
Is the repair complete? | -- | Go to Step 12 | -- |
9 | Replace the heater control unit. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to Step 12 | -- |
10 | Replace the corresponding control cable. Refer to Temperature Control Cable Replacement , Mode Control Cable Replacement or Vent Control Cables Replacement . Is the repair complete? | -- | Go to Step 12 | -- |
11 |
Is the action complete? | -- | Go to Step 12 | -- |
12 | Perform the functional test. Refer to Function Test . Is the action complete? | -- | System OK | -- |