Removal Procedure
- Discharge and recover
the refrigerant. Refer to Refrigerant Recovery and Recharging
.
- Disconnect the pipe fitting at the condenser outlet.
- Remove the bolt and the receiver/dryer inlet pipe (4) from the
receiver/dryer.
Installation Procedure
- Coat new O-rings with
mineral base 525 viscosity refrigerant oil.
- Install the O-rings to the receiver/dryer inlet pipe (4).
- Install the receiver/dryer inlet pipe to the receiver/dryer. Secure
with the bolt.
- Connect the pipe fitting at the condenser outlet.
- Evacuate and recharge the air conditioning (A/C) system. Refer
to Refrigerant Recovery and Recharging
.
- Operate the A/C system and inspect for refrigerant leaks. Refer
to
Leak Testing
.