Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Was the Charging System Check performed? | -- | Go to Step 2 | Go to Charging System Check |
2 |
Does the charge indicator light? | -- | Go to Step 3 | Go to Step 5 |
3 |
Is battery voltage present? | -- | Go to Step 4 | Go to Step 9 |
4 | Remove the generator and replace the IC regulator. Refer to Generator Replacement and Generator Overhaul . Is the repair complete? | -- | Go to Charging System Check | -- |
5 |
Does the charge indicator light? | -- | Go to Step 6 | Go to Step 7 |
6 | Repair the open in the WHT/RED wire between the instrument cluster connector 1 terminal 1 and the generator. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Charging System Check | -- |
7 | Test for an open in the BLK/WHT wire between the instrument cluster connector 1 terminal 2 and fuse block 2. Is an open present? | -- | Go to Step 10 | Go to Step 8 |
8 | Inspect the instrument cluster printed circuit for cracks and bad connections. Repair or replace as necessary. Is the repair complete? | -- | Go to Charging System Check | -- |
9 | Repair the open in the BLK/WHT wire between the generator and fuse block 2. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Charging System Check | -- |
10 | Repair the open. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Charging System Check | -- |