Step | Action | Value(s) | Yes | No | ||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | Did you perform the Instrument Cluster Diagnostic System Check? | -- | Go to Step 2 | |||||||||
2 | Inspect the following circuits for a short to ground or B+:
Was a fault found in any of the wiring? | -- | Go to Step 3 | Go to Step 4 | ||||||||
3 | Repair the wiring. Is the repair complete? | -- | -- | |||||||||
4 | Inspect the following terminals for proper terminal contact:
Were the terminal contacts OK? | -- | Go to Step 6 | Go to Step 5 | ||||||||
5 | Repair the poor terminal connection. Is the repair complete? | -- | -- | |||||||||
6 | Replace the instrument cluster. Refer to Instrument Cluster Replacement . Is the repair complete? | -- | -- |