Horns Circuit Description Chevrolet
Battery voltage is applied at all times to the horn relay
at the following terminals:
A ground is placed on the horn relay coil at terminal F8 when
one of the following actions occur:
• | A horn switch is pressed |
• | The body control module (BCM) initiates a tamper/alarm cycle |
The horn relay contacts close. This action applies battery voltage to
the horns. The horns continue to sound until one of the following actions
occur:
• | The horn switch is released. |
• | The tamper/alarm cycle ends. |
For Pontiac horn circuit description refer to
Horns Circuit Description
Horns Circuit Description Pontiac
Battery voltage is applied at all times to
the horn relay at the following terminals:
A ground path is provided to the horn relay coil at terminal F8
under the following conditions:
• | When the inflator module is pressed against a spring loaded ground
plate in the steering wheel. |
• | When the BCM initiates a tamper/alarm cycle |
The horn relay contacts close. This action applies battery voltage to
the horns. The horns continue to sound until one of the following actions
occur:
• | The inflator module is released. |
• | The tamper/alarm cycle ends. |