The body control module (BCM) monitors CKT 195 as an input in order to determine if the door lock relay circuit is grounded. When CKT 195 is shorted to ground the BCM sets DTC B3137.
All of the following conditions must be met:
• | When CKT 195 is shorted to ground. |
• | The system voltage must be between 9-16 volts. |
• | The above conditions must be met for 0.25 seconds. |
• | The lock system does not function properly. |
• | DTC 3137 stores in BCM memory. |
• | A current DTC clears after the next fault free ignition cycles. |
• | A history DTC clears after 100 consecutive ignition cycles without a fault present. |
• | Clear the history and current DTC using a Scan Tool . |
• | A Scan Tool reads class 2 messages with the ignition switch in the RUN position. |
• | UsingJ 39200 , compare the scan tool values to the actual BCM values. |
• | Perform a visual check of the wiring and connectors |
The numbers below refer to the same numbers in the diagnostic table
This step determines if the door lock relay is operating properly
This step determines an open in CKT 195 within the left IP wiring harness junction block.
This step determines a short to ground in CKT 195 between the left IP wiring harness junction block and the Body Control Module (BCM).
Step | Action | Value(s) | Yes | No | ||
---|---|---|---|---|---|---|
Important: A short to ground will cause an open fuse(s). Before performing this diagnostic procedure, inspect the fuse(s) for an open. | ||||||
1 | Was the Body Control Module (BCM) System Check performed? | -- | Go to Step 2 | |||
2 | Was the Power Door Locks System Check performed? | -- | Go to Step 3 | Go to Power Door Locks System Check in Doors | ||
3 | Do the door lock actuators operate properly? | -- | Go to Step 11 | Go to Step 4 | ||
Replace the door unlock relay with a known good relay from the left IP wiring harness junction block. Do the door lock actuators operate properly? | -- | Go to Step 5 | Go to Step 6 | |||
5 | Replace the door unlock relay. Is the repair complete? | -- | Go to Step 11 | -- | ||
Does the test lamp light? | -- | Go to Step 7 | Go to Step 8 | |||
7 | Replace the left IP wiring harness junction block. Is the repair complete? | -- | Go to Step 11 | -- | ||
Is the measured resistance equal to the specified value? | ∞ | Go to Step 10 | Go to Step 9 | |||
9 | Repair the short to ground in CKT 195 between the BCM connector C3 terminal A8 and the left IP wiring harness junction block. connector C1 terminal F10. Refer to Wiring Repairs in Wiring Systems. Is the repair complete? | -- | Go to Step 11 | -- | ||
10 | Replace the BCM. Refer to the following procedures:
Is the repair complete? | -- | -- | |||
11 |
Is the DTC cleared from the memory? | -- | -- |