Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Interior Lights Schematics Connector End View Reference: Master Electrical Component List in Wiring Systems | |||
1 | Did you perform the Lighting Systems Diagnostic System Check? | Go to Step 2 | |
2 | Place the appropriate reading lamp in the ON position. Does the reading lamp operate properly? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 | Does the courtesy lamp function of the inoperative reading lamp operate properly? | Go to Step 4 | |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 | Inspect for poor connections at the harness connector of the reading switch. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 8 | Go to Step 7 |
6 | Repair an open or high resistance in the ground circuit of the reading lamp switches. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you correct the condition? | Go to Step 8 | -- |
7 | Replace the appropriate reading switch. Refer to Roof Side Rail Lamp Replacement . Did you complete the replacement? | Go to Step 8 | -- |
8 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 2 |