Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Did you perform the Instrument Cluster System Check? | -- | Go to Step 2 | |
2 |
Does the CHECK GAUGES indicator illuminate? | -- | Go to Step 3 | Go to Step 4 |
3 |
Does the CHECK GAUGES indicator illuminate? | -- | Go to Step 5 | Go to Step 7 |
4 | Inspect the instrument cluster connector for proper terminal contact. Was a poor connection found? | -- | Go to Step 8 | Go to Step 9 |
5 | Inspect for an open in CKT 35 (DK GRN). Was there a problem with CKT 35? | -- | Go to Step 10 | |
6 | Inspect for an open in CKT 25 (BRN). Was there a problem with CKT 25? | -- | Go to Step 11 | |
7 | Inspect the instrument cluster connector for proper terminal contact. Was a poor connection found? | -- | Go to Step 8 | Go to Step 9 |
8 | Repair the instrument cluster terminal. Refer to Terminal Repair in Wiring Systems. Is the repair complete? | -- | -- | |
9 | Replace the instrument cluster. Refer to Instrument Cluster Replacement in Instrument Panel, Gauges, and Console. Is the repair complete? | -- | -- | |
10 | Repair the open in CKT 35 (DK GRN). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | -- | |
11 | Repair the open in CKT 25 (BRN). Refer to Repairing Damaged Wire Insulation in Wiring Systems. Is the repair complete? | -- | -- |