Step | Action | Value(s) | Yes | No | ||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Important:
| ||||||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | Go to Diagnostic System Check | ||||||||||||||||
2 |
Does the scan tool indicate that the Commanded Blower data parameter is greater than the specified value? | 100% | Go to Step 3 | |||||||||||||||||
3 |
Does the airflow change discharge locations? | -- | Go to Step 4 | Go to Air Delivery Improper | ||||||||||||||||
4 |
Important:: Outside air temperature must be above 7°C (45°F).
Does the A/C compressor operate? | -- | Go to Step 5 | |||||||||||||||||
5 | With a scan tool, observe the ECT data parameter in the powertrain control module data list. Does the scan tool indicate that the ECT data parameter is within the specified range? | 87-98°C (188-208°F) | Go to Step 6 | Go to Symptoms in Engine Cooling | ||||||||||||||||
6 | Is the defrost airflow warm? | -- | Go to Step 7 | Go to Heating Insufficient | ||||||||||||||||
7 | Is the defrost airflow sufficient and is the left defrost airflow similar to the right defrost airflow at the defroster grille and side window outlets? | -- | Go to Step 10 | Go to Step 8 | ||||||||||||||||
8 |
Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 9 | ||||||||||||||||
9 | Inspect the mode door actuator for binding or mechanical failure. Refer to Mode Actuator Replacement . Did you find and correct the condition? | -- | Go to Step 11 | Go to Step 10 | ||||||||||||||||
10 |
Does the system operate properly? | -- | System OK | Go to Symptoms | ||||||||||||||||
11 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |