Step | Action | Value(s) | Yes | No | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Schematic Reference: HVAC Schematics Connector End View Reference: HVAC Connector End Views DEFINITION: Temperature variation between driver and passenger A/C or heater outlets. | ||||||||||||||||
1 | Did you perform the HVAC Diagnostic System Check? | -- | Go to Step 2 | |||||||||||||
2 |
Important:: In order to execute the HVAC Recalibration command, the scan tool disrupts keep alive memory (KAM) causing DTC B1652 (Loss of KAM) to be set as history.
Does the scan tool display DTC B1340, B1341, B1343, or B1344? | -- | Go to Step 3 | |||||||||||||
3 | Did the customer concern occur during A/C mode operation? | -- | Go to Step 4 | Go to Step 10 | ||||||||||||
4 |
Important:: Ambient air temperature must be above 5°C (41°F).
Are the right and left center panel outlet temperatures similar? | -- | System OK | Go to Step 5 | ||||||||||||
5 | Perform the A/C system performance test. Refer to Air Conditioning (A/C) System Performance Test in Heating, Ventilation and Air Conditioning. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 6 | ||||||||||||
6 | Inspect the air temperature sensors for proper installation. Refer to the following procedures: Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 7 | ||||||||||||
7 |
Does the scan tool indicate that the Right and Left Solar Sensor data parameters are more than the specified value? | 230 Counts | Go to Step 8 | Go to Step 18 | ||||||||||||
8 |
Do the counts change similarly and correspond to the proper sunload sensor? | -- | Go to Step 9 | Go to Step 18 | ||||||||||||
9 |
Does the scan tool indicate that the sensor temperatures vary from the thermometer temperatures by less than the specified value? | 3°C (5°F) | System OK | Go to Step 16 | ||||||||||||
10 | Inspect the cooling system for the following conditions:
Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 11 | ||||||||||||
11 |
Are the right and left outlet temperatures similar? | -- | System OK | Go to Step 12 | ||||||||||||
12 | Check the upper right, upper left, lower right, and lower left air temperature sensors for proper installation. Refer to the following procedures: Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 13 | ||||||||||||
13 |
Does the scan tool indicate that the Right and Left Solar Sensor data parameters are more than the specified value? | 230 Counts | Go to Step 14 | Go to Step 18 | ||||||||||||
14 |
Do the counts change similarly and correspond to the proper sunload sensor? | -- | Go to Step 15 | Go to Step 18 | ||||||||||||
15 |
Does the scan tool indicate that the sensor temperatures vary from the thermometer temperatures by less than the specified value? | 3°C (5°F) | System OK | Go to Step 16 | ||||||||||||
16 | Inspect for poor connections at the harness connector of the suspect temperature sensor. Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 17 | ||||||||||||
17 | Test the suspect temperature sensor resistance. Refer to Sensor Resistance Table . Is the resistance measurement near the value in the Sensor Resistance Table? | -- | Go to Step 19 | Go to Step 21 | ||||||||||||
18 | Inspect for poor connections at the harness connector of the suspect sunload sensor . Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 20 | ||||||||||||
19 | Inspect for poor connections at the harness connectors of the instrument panel integration module (IPM). Refer to Testing for Intermittent Conditions and Poor Connections and Connector Repairs in Wiring Systems. Did you find and correct the condition? | -- | Go to Step 23 | Go to Step 22 | ||||||||||||
20 | Replace the suspect sunload sensor. Refer to Sun Load Sensor Replacement - Left Side or Sun Load Sensor Replacement - Right Side . Did you complete the replacement? | -- | Go to Step 23 | -- | ||||||||||||
21 | Replace the temperature sensor. Refer to the following procedures: Did you complete the replacement? | -- | Go to Step 23 | -- | ||||||||||||
22 |
Important:: Perform the recalibration procedure for the replacement IPM. Replace the IPM. Refer to Instrument Panel Module Replacement in Body Control System. Did you complete the replacement? | -- | Go to Step 23 | -- | ||||||||||||
23 | Operate the system in order to verify the repair. Did you correct the condition? | -- | System OK | Go to Step 2 |