EN-45059 Angle Meter
For equivalent regional tools, refer to Special Tools.
Note:
• The block assembly surface must be free of contamination prior to applying the sealer. • Install and align the bedplate to block within 20 minutes of applying the sealer. • The bedplate must be fastened to final torque specification within 60 minutes of applying the sealer.
Caution: Refer to Fastener Caution in the Preface section.
7.1. | Tighten the crankshaft bearing bolts a first pass in sequence to 20 N·m (15 lb ft). |
7.2. | Using the EN-45059 meter , tighten the crankshaft bearing bolts a final pass in sequence an additional 70 degrees. |