Step | Action | Value(s) | Yes | No |
---|---|---|---|---|
1 | Inspect the fuse B3-B4 in the fuse block. Is the fuse open? | -- | Go to Step 2 | Go to Step 3 |
2 | Repair a short to ground in circuit 41. Is the repair complete? | -- | Go to Functional Check | -- |
3 |
Does the measured voltage vary within the specified range? | 1-12 V | Go to Step 4 | Go to Step 5 |
4 |
Is the measured voltage within the specified range? | 9-14 V | Go to Step 6 | Go to Step 7 |
5 |
Is the measured voltage within the specified range? | 9-14 V | Go to Step 13 | Go to Step 12 |
6 | Connect a DMM between the front left temperature actuator harness connector between terminal 10 and terminal 7 . Is the measured voltage within the specified range? | 9-14 V | Go to Step 8 | Go to Step 9 |
7 | Repair a poor connection or an open in circuit 41 between S233 and the front left temperature actuator harness connector terminal 10. Is the repair complete? | -- | Go to Functional Check | -- |
8 |
Does the measured voltage vary within the specified range? | 1-12 V | Go to Step 10 | Go to Step 11 |
9 | Repair a poor connection or an open in circuit 1450 between the front left temperature actuator harness connector terminal 7 and G200. Is the repair complete? | -- | Go to Functional Check | -- |
10 |
Is the repair complete? | -- | Go to Functional Check | -- |
11 | Repair a poor connection or an open in circuit 1199 Is the repair complete? | -- | Go to Functional Check | -- |
12 | Repair a poor connection or an open in circuit 41 between S233 and the HVAC control assembly harness connector C2 terminal C. Is the repair complete? | -- | Go to Functional Check | -- |
13 |
Is the circuit shorted to ground? | -- | Go to Step 14 | Go to Step 15 |
14 | Repair a short to ground in circuit 1199. Is the repair complete? | -- | Go to Functional Check | -- |
15 | Replace the front HVAC control assembly. Refer to Control Assembly Replacement . Is the repair complete? | -- | Go to Functional Check | -- |