Step | Action | Value(s) | Yes | No | ||||||
---|---|---|---|---|---|---|---|---|---|---|
1 | Perform the Instrument Cluster System Check. Is the system check complete? | -- | Go to Step 2 | |||||||
2 |
Does the test lamp light (bulb check)? | -- | Go to Step 4 | Go to Step 3 | ||||||
3 | Measure the voltage from the instrument cluster connector C1 terminal F15 to ground. Does the voltage equal the specified value? | 12 V | Go to Step 7 | Go to Step 6 | ||||||
4 | Inspect the following instrument cluster terminals for proper contact.
Are the contacts OK? | -- | Go to Step 5 | -- | ||||||
5 | Replace the instrument cluster. Is the repair complete? | -- | -- | |||||||
6 | Inspect CKT 39 (PNK) for an open or short to ground. Is the wiring OK? | -- | -- | |||||||
7 |
Is the resistance less than the specified value? | 5 ohms | Go to Engine Controls | Go to Step 8 | ||||||
8 | Inspect CKT 1173 (BRN/WHT) for an open. Is the wiring OK? | -- | -- | |||||||
9 | Repair the wiring. Is the repair complete? | -- | -- |