Removal Procedure
Caution: Refer to SIR Inflator Module Handling and Storage Caution in the Preface section.
Caution: Refer to SIR Caution in the Preface section.
Caution: A deployed dual stage inflator module will look the same whether one or both
stages were used. Always assume a deployed dual stage inflator module has an active
stage 2. Improper handling or servicing can activate the inflator module and cause
personal injury.
- Disable the SIR system. Refer to
SIR Disabling and Enabling
.
- Remove the I/P retainer. Refer to
Instrument Panel Retainer Replacement
in Instrument Panel, Gages and Console.
- Note the wire harness routing position on the I/P module, to help in assembly.
- Remove the I/P module mounting fasteners.
- Remove the I/P module from the I/P.
Installation Procedure
- Route the I/P module pigtail down through the I/P.
- Install the I/P module to the instrument panel.
Notice: Use the correct fastener in the correct location. Replacement fasteners
must be the correct part number for that application. Fasteners requiring
replacement or fasteners requiring the use of thread locking compound or sealant
are identified in the service procedure. Do not use paints, lubricants, or
corrosion inhibitors on fasteners or fastener joint surfaces unless specified.
These coatings affect fastener torque and joint clamping force and may damage
the fastener. Use the correct tightening sequence and specifications when
installing fasteners in order to avoid damage to parts and systems.
- Install the I/P module mounting fasteners.
Tighten
Tighten the fasteners to 9 N·m (80 lb in).
- Route the I/P module wiring harness in place to secure the I/P module yellow 2-way connector clip.
- Install the I/P retainer. Refer to
Instrument Panel Retainer Replacement
in Instrument Panel, Gages and Console.
- Install the I/P module yellow connector to the vehicle harness yellow connector.
- Install the CPA to the instrument panel module connector.
- Enable the SIR system. Refer to
SIR Disabling and Enabling
.
- After replacing the module, deploy the old module before disposal. If the module was replaced under warranty, fully deploy and dispose of the module after the required retention period. Refer to
Inflator Module Handling and Scrapping
for proper disposal.