Step | Action | Yes | No |
---|---|---|---|
Schematic Reference: Engine Cooling Schematics Connector End View Reference: Cooling System Connector End Views DEFINITION: The afterboil coolant pump does not operate under certain conditions. | |||
1 | Did you perform the Engine Cooling Diagnostic System Check? | Go to Step 2 | |
2 |
Does the afterboil coolant pump operate? | Go to Testing for Intermittent Conditions and Poor Connections in Wiring Systems | Go to Step 3 |
3 |
Does the afterboil coolant pump operate? | Go to Step 11 | Go to Step 4 |
4 |
Does the test lamp illuminate? | Go to Step 5 | Go to Step 6 |
5 | Connect a 5 amp fused jumper wire between the battery positive voltage circuit of the afterboil relay and the afterboil coolant pump supply voltage circuit of the afterboil relay. Does the afterboil coolant pump operate? | Go to Step 13 | Go to Step 9 |
6 | Test the control circuit of the afterboil relay for an open or short to voltage. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 7 |
7 | Test the battery positive voltage circuit of the afterboil relay for an open or a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 8 |
8 | Test the voltage supply circuit of the afterboil coolant pump for a short to ground. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 11 |
9 | Test the voltage supply circuit of the afterboil coolant pump for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 10 |
10 | Test the ground circuit of the afterboil coolant pump for an open. Refer to Circuit Testing and Wiring Repairs in Wiring Systems. Did you find and correct the condition? | Go to Step 14 | Go to Step 12 |
11 | Replace the HVAC Control Module. Refer to HVAC Control Module Replacement in HVAC Systems - Automatic. Did you complete the replacement? | Go to Step 14 | -- |
12 | Replace the afterboil coolant pump. Refer to Afterboil Coolant Pump Replacement . Did you complete the replacement? | Go to Step 14 | -- |
13 | Replace the afterboil relay. Did you complete the replacement? | Go to Step 14 | -- |
14 | Operate the system in order to verify the repair. Did you correct the condition? | System OK | Go to Step 3 |